Documentation / Console reference

Probes

A probe is a sensor that Neti runs at regular intervals against a service: a ping, a TCP port, a web page, a database, a mail server, a WireGuard peer. The Probes section tells you at a glance what is up and what is down, keeps 30 days of history and, if you want, sends an alert by email or Telegram when a service stops answering and another message when it comes back. The checks start from the Neti server, so they also reach the services behind the WireGuard tunnel, which nobody can monitor from outside.

Where: menu Probes. Permission to see it: View Probes (view.db; Viewer, Operator and Admin roles). To add, edit, test, pause and delete probes: Add or edit Probes and their notifications (manage.probes; Operator and Admin). The recipients of the notifications are defined in Settings → Notifications (see Settings).

The Probes page: summary tiles and the list of probes

Summary tiles

Total
How many probes exist.
Up
Probes whose last checks succeeded.
Down
Probes that reached their failure threshold. The number turns red when it is not zero.
Pending / paused
Two numbers: probes that have not decided yet (just created, just resumed, or with a changed target) and probes that are paused.

Probe list

One row per probe, in alphabetical order. The page reloads by itself every minute (not while the add/edit dialog is open).

Status
UP (green), DOWN (red), pending (gray: waiting for enough results) or pause (gray: the probe is paused). See how the status is decided.
Probe
The name (a link to the detail page); below it the type, the message of the last check and how long ago it ran, or waiting for the first check.
Target
Host and port that are checked (host only for the types without a port).
Frequency
How often the probe runs.
Latency
The time measured by the last check, in milliseconds, if it succeeded. What is measured depends on the type.
24h, 7d
Availability over the last 24 hours and 7 days: successful checks divided by all the checks recorded in the period. Green from 99.5%, yellow from 95%, red below; a dash when there are no results.
Latest results
A small chart of the last 60 checks: a green bar for each success, as tall as its latency; a full-height red bar for each failure. Hover over a bar for time and value.
🔔
The bell is shown when notifications are enabled for the probe.
test
Runs the probe at once and shows the result at the top of the page: OK or FAILED, the message and the time. A manual test is not recorded in the history, does not change the status and sends no notification.
edit
Opens the Edit probe dialog.
pause / resume
A paused probe is not checked and sends nothing. Pausing clears the current status and failure count; when it is resumed the probe starts again from pending and runs within a minute.

The + Add probe button at the top right opens the Add probe dialog.

Add probe / Edit probe

Fields common to all types

Name
Required, at most 80 characters. It is the name used in the list and in the notifications.
Service type
What to check and how, grouped as Network, Web, Database and Services. See Probe types. Choosing a type proposes its usual port and shows the options of that type.
IP or host name
The machine to check: an IPv4 or IPv6 address, or a host name. For the WireGuard type the field is called WireGuard IP of the peer, for DNS DNS server (IP). The menu ↳ choose an existing one… fills the field with an address Neti already knows: WireGuard peers, servers of Remote access, hosts already used in other probes.
Port
1–65535. Not shown for Ping and WireGuard tunnel, which have no port.
Check frequency
Every N minutes or hours; N from 1 to 1440. Default: every minute, which is also the minimum.
Timeout (seconds)
How long to wait for the service: 1–30, default 5. Raise it for slow services or slow links, so that a slow answer is not counted as a failure.
Threshold
consider the service down after N consecutive failures: 1–100, default 3. A single failed check triggers nothing; the probe goes DOWN, and the alert is sent, only when the failures in a row reach this number. With a check every minute and threshold 3, an outage is reported after about three minutes.
🔔 Enable notifications
Off by default. When on, the options below appear and at least one recipient must be chosen.
Repeat while it stays down
repeat every N hours or days (1–365): a reminder is sent at that interval for as long as the service stays down. Unchecked (the default): no repeat, only the first alert.
Recipients
The email addresses and Telegram chats defined in Settings → Notifications; tick those that must receive the messages of this probe. If the list is empty, add recipients there first.
Save probe
Saves; the first check starts within a minute. Changing the type, the host or the port of an existing probe resets its status to pending; the history is kept. cancel, close ✕ or the Esc key close the dialog without saving.

Probe types

No type needs a user name or a password: the probes check that the service answers in the way its protocol expects, without signing in.

GroupTypeProposed portThe check succeeds whenLatency is
NetworkPing (ICMP)nonethe host answers the pings and the packet loss does not exceed the accepted maximumaverage round-trip time
NetworkTCP port80the TCP connection opensconnection time
NetworkWireGuard tunnel (handshake)nonethe peer with that tunnel address had a handshake recently enoughnot measured
WebHTTP80the answer has one of the expected status codes and, if set, contains the expected texttotal time of the request
WebHTTPS443as HTTP, over TLStotal time of the request
WebTLS certificate (expiry)443the certificate presented is not expired and does not expire within the chosen number of daystime of the TLS handshake
DatabaseMySQL / MariaDB3306the server sends its MySQL greeting (a server that answers but refuses connections from Neti also counts as up: the service is alive)connection time
DatabasePostgreSQL5432the server answers the PostgreSQL protocolconnection time
DatabaseMicrosoft SQL Server1433the server answers the SQL Server pre-login; the message reports its versionconnection time
DatabaseRedis6379the server answers a PING (also when it asks for authentication)connection time
ServicesSSH22the server sends its SSH bannerconnection time
ServicesSMTP25the server greets with code 220connection time
ServicesIMAP143the server greets with OKconnection time
ServicesPOP3110the server greets with +OKconnection time
ServicesFTP21the server greets with code 220connection time
ServicesRDP (Remote Desktop)3389the TCP connection opensconnection time
ServicesDNS (query)53the DNS server answers the query without error and with at least one recordtime of the query

The database and service types check the protocol, not just the port: a port that is open but answers something else is a failure.

Options of HTTP and HTTPS

Path
The path to request, default / (at most 300 characters). Choose a light page that proves the application works, for example its sign-in page or a health address.
Host header (virtual host)
Optional. The site name to ask for when the host is an IP address that serves several sites, for example app.example.com. The request is sent to the IP of the probe but with that name, also in the TLS handshake.
Expected HTTP codes
Default 200-399. One or more codes or ranges separated by commas, for example 200, 200,301 or 200-299,401. Redirects are not followed: a 301 or 302 is the answer that is evaluated.
Text expected in the page (optional)
If filled in (at most 200 characters), the check succeeds only when the body of the answer contains exactly that text, upper and lower case included. Useful to tell a working page from an error page that still answers 200.
verify the certificate (needs a valid name in the Host header)
HTTPS only, off by default: any certificate is accepted, including self-signed ones, which is what backends behind the tunnel usually have. When on, the certificate must be valid for the name requested, so fill in the Host header (or use a host name as host).

Options of TLS certificate (expiry)

Certificate name (SNI)
Optional. The name to ask for in the TLS handshake, when the server has several certificates. If empty and the host is a name, that name is used.
Alert if it expires within (days)
1–365, default 14. The check fails when the certificate expires within that many days, or is already expired. The chain of the certificate is not verified: only the dates count.

Options of Ping

Packets per check
1–10, default 3.
Maximum accepted loss (%)
0–99, default 50. The check fails when more packets than this are lost, and always when none comes back.

Options of DNS

Name to resolve
Required: the name to ask the DNS server for, for example example.com.
Record type
A, AAAA, MX, TXT, NS or CNAME. The query is sent over UDP.

Options of WireGuard tunnel

Alert if no handshake for (seconds)
30–86400, default 300. As host enter the WireGuard IPv4 address of the peer (for example 10.9.0.5). The check fails when the last handshake of that peer is older than this, when the peer has never connected, or when no peer has that address. With keepalive on, WireGuard renews the handshake about every 2 minutes: 300 seconds leaves a margin against false alerts.

Status and notifications

  • A new probe is pending. The first successful check makes it UP.
  • Each failed check increases a counter; a success resets it. When the counter reaches the threshold the probe becomes DOWN. The outage is counted from the first failure of the series.
  • With notifications enabled, an alert is sent when the probe becomes DOWN, with the error, the number of consecutive failures and since when the service is down. If notifications are enabled on a probe that is already DOWN, the alert is sent at the next failed check.
  • If a repeat is set, a reminder follows at that interval while the probe stays DOWN.
  • At the first successful check after an outage the probe goes back to UP and, if an alert had been sent, a resolved message goes to the same recipients, with how long the outage lasted.
  • Emails use the SMTP server of Neti; Telegram messages use the Telegram settings of Settings → Notifications. Every message sent or not delivered is written in the Events of the probe.

Detail page of a probe

Click the name of a probe in the list. The title shows the name and the status (UP, DOWN, pending or PAUSED); Probes › goes back to the list.

Target
Host and port; below, the type, the frequency and the failure threshold.
Availability
The percentage of successful checks over 24 hours, 7 days and 30 days. Below: for how long the service has been down, or how long ago the last check ran, or never run.
Notifications
🔔 active or disabled; when active, the recipients (✉ email, ✈ Telegram) and the repeat interval or no repeat. no valid recipient means the recipients chosen for the probe have been deleted from the settings: edit the probe and choose others.
Last 30 days
One bar per day with the availability of that day: green from 99.5%, yellow from 95%, red below, gray when there is no data. Hover for date and value.
Last 24 hours
The chart of every check of the last 24 hours (green: success and latency; red: failure), with the number of checks and how many failed.
Events
The last 40 events of the probe, newest first: 🔴 went down, 🟢 came back (with the duration of the outage), 🔔 notification sent or not delivered (with the recipient and the reason), ⏸ paused, ▶ resumed.
Latest results
The last 25 checks: time, result, latency and message.
Edit
Opens the Edit probe dialog.
Test now
Runs the probe at once and shows the result; nothing is recorded and no notification is sent.
⏸ Pause / ▶ Resume
Stops and restarts the checks of this probe.
Delete
After confirmation deletes the probe together with its history and events.

Good to know

  • The checks are started every minute by a system job on the Neti server, up to 8 at a time. Each probe runs at its own frequency, aligned to the minute.
  • The results are kept for 30 days, the events for 90 days.
  • The checks run without privileges; only the WireGuard type asks the system agent for the state of the tunnel.
  • The target sees the checks arrive from Neti: from its tunnel address for services behind WireGuard. HTTP checks identify themselves as Neti-probe/1.0, so you can recognize or exclude them in the logs of the backend.
  • A database that listens only locally on its own server shows as unreachable: this is normal, and safer. Monitor it only if it is meant to be reached from Neti.
  • Problems of the job itself (not of the services) are in Logs → Background jobs → Probes (errors of the every-minute run). The emails sent are in Logs → Email.
  • Adding, editing, pausing, resuming and deleting a probe are recorded in Activity.
  • Remote backups (Neti Pro, see Neti Pro) do not include the measurements of the probes: after a restore they build up again in a few days.

How to monitor a web backend behind the tunnel

  1. Press + Add probe and give it a name.
  2. Choose HTTPS (or HTTP) and pick the backend from ↳ choose an existing one…, or type its tunnel address.
  3. If the backend serves several sites, write the site name in Host header (virtual host).
  4. Set Path to a page that proves the application works and, if you can, a Text expected in the page.
  5. Tick 🔔 Enable notifications, choose the recipients and, if you want reminders, the repeat.
  6. Press Save probe, then test in the list to see the result at once.

A second probe of type WireGuard tunnel (handshake) on the same address tells you whether an outage is the application or the tunnel.

Troubleshooting

The probe stays "pending"
It has not run yet (wait a minute), or it has failed fewer times than the threshold and has never succeeded. Use test to read the error.
HTTP probe fails with an unexpected code
The backend may redirect (301/302) or ask for a sign-in (401/403). Add the code to Expected HTTP codes, or change the path. If the backend answers with the wrong site, fill in the Host header.
HTTPS probe fails on the certificate
Certificate verification is on and the backend has a self-signed certificate or one for another name: turn the verification off, or set the right name in the Host header.
Ping fails but the service works
Many servers and firewalls do not answer pings. Use a TCP or protocol probe instead.
False alerts now and then
Raise the Threshold or the Timeout; for WireGuard raise the handshake age.
The service is down but no message arrived
Check that the bell is shown in the list, then open the probe and read Events: a notification that was not delivered is written there with the reason. Test the recipients in Settings → Notifications.
"Notifications are on: choose at least one recipient"
The probe cannot be saved with notifications enabled and no recipient ticked.
Community

Community

Discussion board. Sign in to open topics and reply.

Loading…

The same account works for Community and Console.

Complete your profile

Your profile

One more step to join the community.

My posts

Your discussions and replies.